Oct 18, 2019 The Rheem Criterion II Plus 2 LXE is a gas furnace with contour comfort control that can be used in at least six different locations. Oil-fired and electric versions are also available. This furnace has an AFUE of 80%.
Help with Rheem Criterion II Troubleshooting submitted 4 years ago by MediocreDane I've got a Criterion II furnace (RGPK-10EAMER) that hasn't been firing for the last few days and I need help trying to figure out what's wrong with it. Wholesale Parts, Supplies & Accessories We offer many wholesale parts, supplies and accessories for the HVAC and Water heating, including quality PROTECH products. Rheem Air Conditioning, Furnace, and Heat Pump Parts & Accessories Manufacturer authorized heating and air. Apr 03, 2010 Rheem Criterion II furnace manual reset limit switch - Answered by a verified HVAC Technician. Rheem Criterion II furnace manual reset limit switch. I have an older Rheem Criterion II gas furnace that will not shut off when the temperature set on the thermastat is reached. I disconnected the thermastat and it still comes on. View and Download Rheem 05EAUER manual online. RGPQ- Series Classic Series Two-Stage Upflow/Horizontal Gas Furnaces. 05EAUER Furnace pdf manual download. Also for: 05nauer, 07eamer, 07namer, 07eamgr, 07namgr, 10eamer, 10namer, 10ebrjr, 10nbrjr, 12earjr, 12narjr, 15earjr, 15narjr. Furnace Rheem CRITERION II PLUS 2 LXE RGPL- SERIES Manual. Find Rheem Furnace Parts at RepairClinic.com. Repair your Rheem Furnace for less. Fast, same day shipping. 365 day right part guaranteed return policy.
Advertising
2
Rheem Manufacturing Company
STANDARD EQUIPMENT
Completely assembled and wired; induced draft; pressure switch; redundant main gas control; blower compartment door safety switch; solid state time on/time off blower control; limit control; manual shut-off valve, pressure regulator for natural and L.P. (propane) gas; transformer; direct drive multi- speed blower motor. Furnaces are equipped with cooling/heating relay and transformer (40VA) ready for air conditioning applications. (Please note: a thermostat is not included as standard equipment.) Flame sensor diagnostics; on-board twinning; fused transformer (secondary), 3rd speed option for continuous fan; common heat/cool terminal.
NOTE: Furnace is not listed for use with fuels other than natural or L.P.
(propane) gas.
The complete terms of limited and other warranties are available at our sales office, or through local installer.
All models can be converted by a qualified Rheem distributor or local service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a Rheem parts distributor.
For L.P. (propane) operation, refer to Conversion Kit Index Form.
NOTE: For natural and L.P. (propane) gas models, standard hot surface ignition
is 100% lockout type.
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED
FOR USE IN MOBILE HOMES
RHEEM CRITERION II 80% DOWNFLOW GAS FURNACE
Heat Exchanger
Draft Inducer Motor
In-Shot Burners
Molded Permanent Filter
Integrated Furnace Control
Direct Spark Ignitor with Remote Sense
Advertising
This manual is related to the following products:
Popular Brands
Popular manuals
Advertising
FORM NO. G11-449 REV. 6
Supersedes Form No. G11-449 Rev. 5
GAS FURNACES
CRITERION
®
II
80.0-82.2% A.F.U.E.
✝
DOWNFLOW GAS FURNACES
The Rheem
®
Criterion
®
II line of downflow gas furnaces is
designed for installation in closets, alcoves, utility rooms, or attics. The design is certified by CSA.
Features
■
Patented heat exchanger, constructed of both stainless and aluminized steel for the maximum in corrosion resistance.
■
Low profile “34 inch” [864 mm] design is lighter and easier to handle, and leaves room for optional equipment.
■
Left or right side gas and electric inlet connections with quick, simple change.
■
Direct Spark ignition models and integrated board with humidifier and electronic air cleaner hookups.
■
Insulated blower compartment helps to reduce jacket loss and noise.
■
Pre-paint galvanized steel cabinet.
■
Molded permanent filter.
■
Grab-holes in doors to aid in easy door removal and replacement.
A variety of cooling coils and plenums designed to use with Rheem Criterion II gas furnaces are available as optional accessories.
✝A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of
Rheem Criterion Ii Gas Furnace User's Manual 2017
Energy test procedures.
RGLH- SERIES
Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kW]